rustsys_cli::proto: the job protocol of the command line

rustsys_cli::proto (crates/apps/rustsys-cli/src/proto/, ADR 0003) is the job protocol between the rustsys command and the engines: typed jobs, their canonical command lines, their execution with events, run records, report loading, text rendering, tables, filters and sort orders. It contains no user interface toolkit and starts no long-lived thread. The synthesis engine is reached only through its view module (PROTO-REQ-0002).

Document Requirements
this file PROTO-REQ-0001 to 0099: jobs, canonical commands, execution, run records
tables.md PROTO-REQ-0100 to 0199: numbers, fields, text, tables, filters

Jobs and commands

PROTO-REQ-0001 A Job is one of Synth and CheckSynth, holding every option that can change a result, with paths as given. Front ends build jobs; only execute runs them.

PROTO-REQ-0002 Source files of this crate name synthesis engine items only through rustsys::view (tested by scanning the sources).

PROTO-REQ-0010 The help text of every job option comes from one table (options), used by the command line's help.

PROTO-REQ-0020 The canonical command of a job is rendered from the job, never from the original arguments: rustsys <product> … with every result-affecting option spelled out, defaults included (--effort, --goal, --delay-relax, --backend, --seed, --cycles, --budget, --model-budget), --threads N when N is not 0, outputs, and nothing about presentation. Arguments are quoted for a POSIX shell so that split(quote(x)) == x for every string x. A job written before an option existed has that option's default.

PROTO-REQ-0021 Executed in the recorded working directory with unchanged inputs, the canonical command reproduces the run's outputs, except run times. A --record run is reproduced in a new run directory; a --run-dir DIR run once DIR no longer holds the run, since a run directory holds one run (PROTO-REQ-0050). An option value that starts with - is written as one word (--label=-x, -D-X) and sources that start with - follow --.

Execution

PROTO-REQ-0030 execute(job, placement, ctx) reads the inputs, runs the engine with the context, writes the outputs atomically (PROTO-REQ-0033) and returns the outcome: exit class, report and text result. Messages go to the observer as Diagnostic events in the order in which they arise; nothing is printed.

PROTO-REQ-0031 Exit classes and statuses: Ok 0, Rejected 1 (input rejected or an output cannot be written), Internal 2 (a panic, or verdict error with internal_error), Negative 3 (verdict not-equivalent), Undecided 5 (verdict undecided), Cancelled 130. The outcome holds the report and the text result for Ok, Negative and Undecided.

PROTO-REQ-0032 The order of effects of a run is: run record with status running (when there is a run directory), the engine, the output files, the final run record. On any error before the outputs are complete, no output file is left half written.

PROTO-REQ-0033 Files are written to a temporary file in the target directory and renamed into place; parent directories are created. JSON is streamed; its bytes equal those of serde_json::to_string_pretty of the same value.

Run records

PROTO-REQ-0050 A run directory holds run.json, the product's outputs that were not named explicitly (netlist.v and report.json for synthesis, check.json for the check) and events.jsonl. --run-dir DIR uses DIR, which must not already hold a run.json (A0007). --record allocates <runs root>/<run id>/ (A0008 without a runs root).

PROTO-REQ-0051 Run ids are <yyyymmdd>T<hhmmss>Z-<product>-<4 hex digits> in UTC, products synth and check-synth; the directory is created atomically and the suffix is incremented on collision.

PROTO-REQ-0052 run.json holds: format rustsys-run, format_version 1, id, product, label, status (running, ok, rejected, internal, negative, undecided, cancelled), exit status, the original arguments, the canonical command, the absolute working directory, the job, program version, compiled runtimes, threads, start and finish times (UTC), load, engine, write and total seconds, inputs (role, path, bytes, 64-bit FNV-1a hash), outputs (role, path), a summary of key figures and message counts per severity.

PROTO-REQ-0053 events.jsonl holds one JSON object per event of the run, in order, with the seconds since the start of the run.

PROTO-REQ-0060 Run references: @ (latest run under the runs root, by start time), @~N (N-th before the latest), @<product> and @<product>~N (the same among runs of one product), an id prefix of at least 4 characters (unique under the runs root), a path to a run directory, or a path to a report file (a run without record: report views only). @ forms and prefixes need a runs root (A0008); an unknown or ambiguous reference is A0006 and lists up to 5 candidates.

PROTO-REQ-0061 --from-run <RUN> completes a job from a finished run: check synth takes sources, front-end options, libraries, top and netlist of a synthesis run. Options given explicitly win. A run of another product or without the needed output is A0009. Recorded relative paths are resolved against the run's working directory.

PROTO-REQ-0062 Loading reads a run directory or a report file. The kind of a report is its format field, or, for reports written before that field existed, the presence of aig_nodes_before (synthesis) or outputs_checked (check synth). Anything else is A0020; a format_version newer than this program reads for the kind (synthesis 1, check synth 2) is A0021.